TIC 4.0
Oil
CONCEPT
Fields | Type | Description | Purpose |
---|---|---|---|
ID (Concept identifier) | M | oil | GRAMMAR |
Concept name | M | Oil | GRAMMAR |
Concept type | M | Substance | GRAMMAR |
Also known as | O | lubricant; grease; coolant; hydraulics; motor oil; engine oil | TIC Description |
Definition | M | Component of the subject in charge of the lubrication and cooling of any of the subject mechanical component. Also used to transmit and distribute energy in hydraulic systems. Oils have a high carbon and hydrogen content and are usually flammable and surface active. | TIC Description |
Further Detail | O | Status is true when the component can do its job properly, so levels, temperature and composition is suitable for doing the job it was designed. | TIC Description |
Required Information | M | SUBJECT; OBSERVED PROPERTY and VALUE | TIC Description |
SUBJECT | Â | #Engine; #CHE #Hinge #Joint #Gearbox #Brake #Rope #Hydraulic components | Â |
POINT OF MEASUREMENT | Â | #input; #internal_in; #internal_out; #output #actual; | Â |
OBSERVED PROPERTY | Â | #status; #temperature; #age; #load spectrum #working hours; #pressure; #leakage #contamination rate #water content #level; #particle; #viscosity | Â |
Value |  | TRUE; FALSE; ºC; ºF; h; %; PSI; bar; Pa; ppm |  |
Related standards | O | Â API, ILSAC, ACEA, JASO, ASTM standards | TIC Description |
Related TIC 4.0 definition | O | Â | TIC Description |
Example | M | che_powersource_oil_output_pressure_PSI: 50 = SPN100; Gage pressure of oil in engine lubrication system as provided by oil pump. Generated by the manufacturers sensor control SW. che_powersource_oil_output_level_%: 50 = SPN98; Ratio of current volume of engine sump oil to maximum required volume. Generated by the manufacturers sensor control SW. che_powersource_oil_output_temperature_ºC: 50 = SPN175; Temperature of the engine lubricant. Generated by the manufacturers sensor control SW. | TIC Description |
Example in the context of the grammar | M | che_powersource_health_oil_output_lowlevel_status: TRUE; JSON example: {
"msg": {
"id": "",
"sender": "",
"timestamp": "2021-04-22T15:38:10.803Z",
"topic": "",
"destinantion": "",
"creationtimestamp": "2021-04-22T15:38:10.803Z",
"starttimestamp": "2021-04-22T15:38:10.803Z",
"endtimestamp": "2021-04-22T15:38:10.803Z"
},
"che": [
{
"id": "",
"name": "",
"number": 0,
"type": "",
"family": "",
"brand": "",
"model": "",
"powersource": [
{
"id": "",
"name": "",
"number": 0,
"type": "",
"family": "",
"brand": "",
"model": "",
"source": "",
"softwareid": "",
"oil": {
"temperature": [
{
"pom": "output",
"pomt": "actual",
"unit": "celsius",
"timestamp": "2021-04-22T15:38:10.803Z",
"value": 0
},
{
"pom": "output",
"pomt": "actual",
"unit": "boolean",
"timestamp": "2021-04-22T15:38:10.803Z",
"value": false
},
{
"pom": "output",
"pomt": "actual",
"unit": "%",
"timestamp": "2021-04-22T15:38:10.803Z",
"value": 0
},
{
"pom": "output",
"pomt": "actual",
"unit": "boolean",
"timestamp": "2021-04-22T15:38:10.803Z",
"value": false
}
],
"pressure": [
{
"pom": "output",
"pomt": "actual",
"unit": "kpa",
"timestamp": "2021-04-22T15:38:10.803Z",
"value": 0
},
{
"pom": "output",
"pomt": "actual",
"unit": "bar",
"timestamp": "2021-04-22T15:38:10.803Z",
"value": 0
},
{
"pom": "output",
"pomt": "actual",
"unit": "boolean",
"timestamp": "2021-04-22T15:38:10.804Z",
"value": 0
}
]
}
}
]
}
]
} | TIC Description |
Link to one or more operational processes | M | Â | TIC Description |
Search tags | M | Â #oil | Technical |
Version / Date | M | 2021.1 - 30/04/2021 | Technical |
Internal TIC Version | M | 20210422 consistency review | Technical |
M = Mandatory
O = Optional
Created by | Edited by | Review / Approve | Published |
 @Pekka Yli-Paunu 2021-02-28 |  |  |  |
 |   @Francisco Blanquer Jaraiz 2021-04-22 |  |  |
Â
Â
© Copyright - TIC 4.0 All rights reserved | Design web by Fundación Valenciaport