CONCEPT

Fields

Type

Description

Purpose

ID (Concept identifier)

M

on_standby

GRAMMAR

Concept name

M

On Standby

GRAMMAR

Concept type

M

status

GRAMMAR

Subject Tag

M

#CHE; #STS; #SC; #RTG; #RMG; #TT; #FKL

GRAMMAR

Also known as

O

On; Not Off; Power On; Ready to work; standby; With power; Engine on; Power supply on

TIC Description

Definition

M

If the main power supply is not currently available but it could be in less than 2 seconds then TRUE else FALSE

TIC Description

Further Detail

O

If the machine is able to supply the energy for normal operation in less than 2 seconds then is consider On_Standby but currently is not supplying the power.

if off is TRUE then on_standby has to be FALSE

TIC Description

Required Information

M

SUBJECT; OBSERVED PROPERTY and VALUE

TIC Description

SUBJECT

 

#CHE; #STS; #SC; #RTG; #RMG; #TT; #FKL; #Gate

 

POINT OF MEASUREMENT

 

affect all the subject so it doesn't make sense to measure in one point.

 

OBSERVED PROPERTY

 

#status; #counter; #duration; #timer; #power; #energy; #distance;

 

Value

 

TRUE; FALSE; real number; integer

 

Related standards

O

 

TIC Description

Related TIC 4.0 definition

O

#off; #on_standby

TIC Description

Example

M

che_on_standby_status: TRUE = the Container Handler Equipment is ready to have the power to work properly in less than 2 seconds but currently is not running.

che_spreader_on_standby_status: TRUE = the Spreader of the Container Handler Equipment is ready to have the power to work properly (lock-unlock-expand-contract) in less than 2 seconds but currently is not running.

che_engine_on_standby_status: FALSE the Engine of the Container Handler Equipment is not ready to have the power to work properly (give power to the crane) in less than 2 seconds, could be off (not able to give power in less than 2) or on (currently giving the power).

TIC Description

Example in the context of the grammar

M

An RTG with the Engine On but the drivers off and the spreader pump off, but the machine is able to warm the drivers and pump in less than 2 seconds automatically

che_on_standby_status: TRUE; che_on_status: TRUE che_spreader_off_status: TRUE; che_spreader_on_status: FALSE che_engine_on_status: TRUE

TIC Description

Link to one or more operational processes

M

Any CHE load or discharge operation.

TIC Description

Search tags

M

#OFF; #Off; #off; #ON; #On; #on; #standby; #running; #working

Technical

Version / Date

M

TIC_Q4_2020 / 15.09.2020

Technical

Internal TIC Version

M

definition technical group

Technical

M = Mandatory

O = Optional

OLD PROPOSAL

ID

37

Name

CHE Activity On

Abbreviation

che.activity.on.command||request||feedback||action.status||counter||timer||energy||distance

Category

Also known as

On; Running; Power On; Engine On

Definition

IF (CHE_Activity_Off.status : False) then True else False

Further Detail

CHE_Activity_On is the opposite of CHE_Activity_Off, when a CHE is not off is on, it doesn't give any extra information. If main power supply is available in less than 2 seconds then true else false. CHE_Activity_Working and CHE_Activity_Working_Idle is under ON, so a machine that is ON only can be Working or Idle. CHE_Activity_On is the contrary of CHE_Activity_Off

Required

Related standards

Related TIC 4.0 definition

HEADER

Identifies the message in origin, destination, time and unique reference (use this link for more information)

Mandatory

Header message timestamp; Header message identifier; Header sender identifier; Header time; Header time start; Header time end

Optional

(Header topic; Header identifier)

SUBJECT

Defines the perimeter and id of the subject (usually defined as a process) (use this link for more information)

Default

Identifier (Abbreviation, Definition, Long definition); Class (Abbreviation, Definition, Long definition, Suitable)

Suitable

Name; Number; Family; Subsystem (Abbreviation, Definition, Long definition, Suitable, Examples)

POINT OF MEASUREMENT

It defines wherein the process (step, place or time) the observed property of the concept is measured (use this link for more information)

Default

IN; Request; Feedback; OUT (scheduled; planning; estimated, calculated; actual; verified)

Optional

Control (from where)

OBSERVED PROPERTY

It is the magnitude of the concept (units, volume, weight, energy, time, etc.) (use this link for more information)

Default

Status; %; Speed; Counter; Distance; Timer; Energy; Average; …

Suitable

Specify units when they are different than the International System

Units

True/False

Draws

(optional) add some draws to explain the concept

Diagrams

(optional) add some process diagram which concept belongs

Attached documents

(optional) add some document to explain the concept

Examples

Human

1.20191205 12:00 London-Gate03 move “get_in” “out=result” actual boxes “1

2.20191205 12:06 London-TZ01 move “occupied” in actual boxes “1

3.20191205 12:18 London-SC74 move “in” actual boxes “1” (waiting for orders)

4.20191205 12:22 London-SC74 move “Lock” actual boxes “1

5.20191205 12:22 London-TZ01 move out actual boxes “1

6.20191205 12:32 London-Yard_A-34B56 move “occupied” in actual boxes “1

JSON: