CONCEPT
Fields | Type | Description | Purpose |
---|---|---|---|
ID (Concept identifier) | M | on_standby | GRAMMAR |
Concept name | M | On Standby | GRAMMAR |
Concept type | M | status | GRAMMAR |
Subject Tag | M | #CHE; #STS; #SC; #RTG; #RMG; #TT; #FKL | GRAMMAR |
Also known as | O | On; Not Off; Power On; Ready to work; standby; With power; Engine on; Power supply on | TIC Description |
Definition | M | If the main power supply is not currently available but it could be and any system of the subject is ready to operate in less than 2 seconds but any of them is not currently ready then TRUE else FALSE | TIC Description |
Further Detail | O | If the machine is able to supply the energy for normal operation in less than 2 seconds then is consider On_Standby but currently is not supplying the power. if On Standby is a special type of On status where the subject is not currently ready but almost. If off is TRUE then on_standby has to be FALSE | TIC Description |
Required Information | M | SUBJECT; OBSERVED PROPERTY and VALUE | TIC Description |
SUBJECT |
| #CHE; #STS; #SC; #RTG; #RMG; #TT; #FKL; #Gate; #Terminal; #MC; #TOS ; #Luminary |
|
POINT OF MEASUREMENT | affect all the subject so it doesn't make sense to measure in one point. | #input;#internal_in ; #internal_out ;#output #schedule; #planning; #estimated; #actual; #performed |
|
OBSERVED PROPERTY |
| #status; #counter; #duration; #timer; #power; #energy#totaltimer #energy; #startevent; #startcounter; #endevent; #endcounter; #distance; |
|
Value |
| TRUE; FALSE; real number; integer |
|
Related standards | O |
| TIC Description |
Related TIC 4.0 definition | O | #off; #on_standby | TIC Description |
Example | M | che_on_standby_status: TRUE = the Container Handler Equipment is ready to have the power to work operate or do its job properly in less than 2 seconds because the power, the control and all of its systems are able to be ready on time but currently is not running. che_spreader_on_standby_status: TRUE = the Spreader of the Container Handler Equipment is ready to have the power to work operate properly (lock-unlock-expand-contract) in less than 2 seconds but currently is not running. che_engine_on_standby_status: FALSE = the Engine of the Container Handler Equipment is not ready to have generate the power to work properly (give power to the crane) the CHE working properly in less than 2 seconds , could be off (not able to give power in less than 2) or on (currently giving the power)but currently is not. | TIC Description |
Example in the context of the grammar | M | An RTG with the Engine and control On but the drivers off and the spreader pump off, but the machine is able to warm the drivers and pump in less than 2 seconds automaticallycabin gate open che_engine_on_standby_status: TRUE; che_drivers_on_status: TRUE FALSE; che_spreadercontrol_offon_status: TRUE; che_spreader_cabingateopen_status: TRUE; che_on_status: FALSE TRUE; che_engineon_onstandby_status: TRUE | TIC Description |
Link to one or more operational processes | M | Any CHE load or discharge operation. | TIC Description |
Search tags | M | #OFF; #Off; #off; #ON; #On; #on; #standby; #running; #working | Technical |
Version / Date | M | TIC_Q4_2020 / 15.09.2020 | Technical |
Internal TIC Version | M | definition technical group | Technical |
...
ID | 37 |
Name | CHE Activity On |
Abbreviation | che.activity.on.command||request||feedback||action.status||counter||timer||energy||distance |
Category | |
Also known as | On; Running; Power On; Engine On |
Definition | IF (CHE_Activity_Off.status : False) then True else False |
Further Detail | CHE_Activity_On is the opposite of CHE_Activity_Off, when a CHE is not off is on, it doesn't give any extra information. If main power supply is available in less than 2 seconds then true else false. CHE_Activity_Working and CHE_Activity_Working_Idle is under ON, so a machine that is ON only can be Working or Idle. CHE_Activity_On is the contrary of CHE_Activity_Off |
Required | |
Related standards | |
Related TIC 4.0 definition |
HEADER
Info |
---|
Identifies the message in origin, destination, time and unique reference (use this link for more information) |
Mandatory | Header message timestamp; Header message identifier; Header sender identifier; Header time; Header time start; Header time end |
Optional | (Header topic; Header identifier) |
SUBJECT
Info |
---|
Defines the perimeter and id of the subject (usually defined as a process) (use this link for more information) |
Default | Identifier (Abbreviation, Definition, Long definition); Class (Abbreviation, Definition, Long definition, Suitable) |
Suitable | Name; Number; Family; Subsystem (Abbreviation, Definition, Long definition, Suitable, Examples) |
POINT OF MEASUREMENT
Info |
---|
It defines wherein the process (step, place or time) the observed property of the concept is measured (use this link for more information) |
Default | IN; Request; Feedback; OUT (scheduled; planning; estimated, calculated; actual; verified) |
Optional | Control (from where) |
OBSERVED PROPERTY
Info |
---|
It is the magnitude of the concept (units, volume, weight, energy, time, etc.) (use this link for more information) |
...