Versiones comparadas

Clave

  • Se ha añadido esta línea.
  • Se ha eliminado esta línea.
  • El formato se ha cambiado.

CONCEPT

Fields

Type

Description

Purpose

ID (Concept identifier)

M

off

GRAMMAR

Concept name

M

Off

GRAMMAR

Concept type

M

status

GRAMMAR

Subject Tag

M

#CHE; #STS; #SC; #RTG; #RMG; #TT; #FKL

GRAMMAR

Also known as

O

Off; Not On; Power Off; Not ready to work; deep standby; No power; Engine off; Power supply off; turned off; Out of operations; idle;

TIC Description

Definition

M

If the main power supply is availableor any system of the subject is not ready to operate in less than 2 seconds then false TRUE else trueFALSE

TIC Description

Further Detail

O

This definition is complementary to “on” concept.

If the machine is not able to supply the energy for normal operation or the “control” of the subject is off or any of the subject systems or subsystems are not ready to run the subject for its normal “job” in less than 2 seconds then is consider On even if there is no main power supply running (ie che_on_standby : true)

This definition is complementary to che_on

it is considered off. If any of the critical components to operate are not “on” then is considered “off”.

TIC Description

Required Information

M

SUBJECT; OBSERVED PROPERTY and VALUE

TIC Description

SUBJECT

#CHE; #STS; #SC; #RTG; #RMG; #TT; #FKL; #Gate; #Terminal; #MC; #TOS ; #Luminary

POINT OF MEASUREMENT

affect all the subject so it doesn't make sense to measure in one point.#input;#internal_in ; #internal_out ;#output

#schedule; #planning; #estimated; #actual; #performed

OBSERVED PROPERTY

#status; #counter; #duration; #timer; #power; #energy; ; #totaltimer #energy; #startevent; #startcounter; #endevent; #endcounter

Value

TRUE; FALSE; integer; real number; integer

Related standards

O

TIC Description

Related TIC 4.0 definition

O

#On#on; #On#on_Standbystandby

TIC Description

Example

M

che_off_status: TRUE = the Container Handler Equipment is not ready to have the power to work operate or do its job properly in less than 2 seconds because no power, no control or any of its systems is not able to be ready on time.

che_spreader_off_status: TRUE FALSE = the Spreader of the Container Handler Equipment is not ready to have automatically the power to work operate properly (lock-unlock-expand-contract) in less than 2 seconds.

che_engine_off_status: FALSE TRUE = the Engine of the Container Handler Equipment is not ready to have generate the power to work properly (give power to the crane) the CHE working properly in less than 2 seconds.

TIC Description

Example in the context of the grammar

M

A An RTG with the Engine On but the drivers off and the spreader pump control off

che_engine_off_status: FALSE; che_drivers_off_status: TRUE; che_spreadercontrol_off_status: TRUE; che_engine_off_status: FALSETRUE

TIC Description

Link to one or more operational processes

M

Any CHE load or discharge operation.

TIC Description

Search tags

M

#OFF; #Off; #off; #ON; #On; #on; #standby; #running; #working

Technical

Version / Date

M

TIC_Q4_2020 / 15.09.2020

Technical

Internal TIC Version

M

definition technical group

Technical

M = Mandatory

O = Optional

OLD PROPOSAL

CONCEPT

ID

36

Name

CHE Activity Off

Abbreviation

che.activity.off.command||request||feedback||action.status||counter||timer||energy||distance

Category

(optional) Tag (Activity, Move, Functional, Operational, OS, etc) groups at a high level the property concept and establish a hierarchy. It is a tag that helps to identify and describe the property. The objective helps the human to classify, find, use the properties. Ie: move; activity; functional, operational, control, TOS. One concept can have several families but must be a closed list.

Also known as

Engine off; power supply off

Definition

If main power supply is available to operate in less than 2 seconds then false else true

Further Detail

If the machine is able to supply the energy for normal operation in less than 2 seconds then is consider On even if there is not main power supply running (ie CHE_Activity_On_Standby : true

This definition is complementary to CHE_Activity_On_Standby

Required

Related standards

Related TIC 4.0 definition

HEADER

Info

Identifies the message in origin, destination, time and unique reference (use this link for more information)

Mandatory

Header message timestamp; Header message identifier; Header sender identifier; Header time; Header time start; Header time end

Optional

(Header topic; Header identifier)

SUBJECT

Info

Defines the perimeter and id of the subject (usually defined as a process) (use this link for more information)

Default

Identifier (Abbreviation, Definition, Long definition); Class (Abbreviation, Definition, Long definition, Suitable)

Suitable

Name; Number; Family; Subsystem (Abbreviation, Definition, Long definition, Suitable, Examples)

POINT OF MEASUREMENT

Info

It defines wherein the process (step, place or time) the observed property of the concept is measured (use this link for more information)

Default

IN; Request; Feedback; OUT (scheduled; planning; estimated, calculated; actual; verified)

Optional

Control (from where)

OBSERVED PROPERTY

Info

It is the magnitude of the concept (units, volume, weight, energy, time, etc.) (use this link for more information)

...