CONCEPT
Fields | Type | Description | Purpose |
---|---|---|---|
ID (Concept identifier) | M | standby | GRAMMAR |
Concept name | M | Standby | GRAMMAR |
Concept type | M | Activity | GRAMMAR |
Also known as | O | On; Not Off; Power On; Ready to work; standby; With power; Engine on; Power supply on; idle; | TIC Description |
Definition | M | If the subject is “On” [If the main power supply and all subject systems are able to operate (do the job it has been designed for) the subject in less than 2 seconds requiring no more (a maximum) than one (not a sequence) operator action] but any (at least one) of them (power supply or subject system) is not currently ready then TRUE else FALSE | TIC Description |
Further Detail | O | On Standby is a special type of On status where the subject is not currently ready but almost and just need a maximum of one operator action (a sequence from the operator is not required just one action). If Off is TRUE then on_standby is FALSE | TIC Description |
Required Information | M | SUBJECT; OBSERVED PROPERTY and VALUE | TIC Description |
SUBJECT |
| #CHE; #Gate; #Terminal; #MC; #TOS ; #Luminary |
|
POINT OF MEASUREMENT |
| #input;#internal_in ; #internal_out ;#output #schedule; #planning; #estimated; #actual; #performed |
|
OBSERVED PROPERTY |
| #status; #counter; #duration; #timer; #totaltimer #energy; #startevent; #startcounter; #endevent; #endcounter; #distance; standby_to_operative_timer = 2 (default) |
|
Value |
| TRUE; FALSE; real number; integer |
|
Related standards | O |
| TIC Description |
Related TIC 4.0 definition | O | #off; #on_standby | TIC Description |
Example | M | che_on_standby_status: TRUE = the Container Handler Equipment is ready to operate or do its job properly in less than 2 seconds because the power, the control and all of its systems are able to be ready on time but currently is not. che_spreader_on_standby_status: TRUE = the Spreader of the Container Handler Equipment is ready to operate properly (lock-unlock-expand-contract) in less than 2 seconds but currently is not. che_engine_on_standby_status: FALSE = the Engine of the Container Handler Equipment is not ready to generate the power to the CHE working properly in less than 2 seconds but currently is not. | TIC Description |
Example in the context of the grammar | M | An RTG with the Engine and control On but the drivers off and the cabin gate open che_engine_on_status: TRUE; che_drivers_on_status: FALSE; che_control_on_status: TRUE; che_cabingateopen_status: TRUE; che_on_status: TRUE; che_on_standby_status: TRUE CHE with the operator seated, engine standby (start-stop system), CHE ready to operate just when driver move the joystick then ON che_engine_on_status: FALSE; che_control_on_status: TRUE; che_seat_operator_on_status: TRUE; che_on_status: TRUE; che_on_standby_status: TRUE CHE with the operator not seated, engine standby (start-stop system), CHE ready to operate just when driver seated and move the joystick then OFF che_engine_on_status: FALSE; che_control_on_status: TRUE; che_seat_operator_on_status: FALSE; che_on_status: FALSE; che_on_standby_status: FALSE | TIC Description |
Link to one or more operational processes | M | Any CHE load or discharge operation. | TIC Description |
Search tags | M | #OFF; #Off; #off; #ON; #On; #on; #standby; #running; #working | Technical |
Version / Date | M | TIC_Q4_2020 / 15.09.2020 | Technical |
Internal TIC Version | M | definition technical group | Technical |
M = Mandatory
O = Optional
JSON:
XML:
MQTT: