TIC 4.0

Ir al final de los metadatos
Ir al inicio de los metadatos

Estás viendo una versión antigua de esta página. Ve a la versión actual.

Comparar con el actual Ver el historial de la página

Versión 1 Siguiente »

CONCEPT

Fields

Type

Description

Purpose

ID (Concept identifier)

M

ambient

GRAMMAR

Concept name

M

Ambient

GRAMMAR

Concept type

M

metadata

GRAMMAR

Also known as

O

External atmosphere, external ambient.

TIC Description

Definition

M

Describes the characteristics or conditions of the air, light and sound in a given location in the surrounding of a subject

TIC Description

Further Detail

O

For example, the air located outside of a reefer container (“cargo|@|TypeReefer” in the TIC4.0 language).

TIC Description

Required Information

M

SUBJECT; OBSERVED PROPERTY; POM; POMT and VALUE

TIC Description

SUBJECT

 

cargo; che; terminal

 

POINT OF MEASUREMENT

 

POM: Output (represents the actual measurement from the sensors)

POMT: actual,

 

OBSERVED PROPERTY

 

Air:

Temperature:

15 degrees Celsius of ambient temperature of the air measured by the reefer container sensor.

cargo|@|ambient|air|temperature|#name#sensor1|#unit#celsius|output|actual|value = 15

Humidity:

80% of humidity in the ambient of the air measured by the reefer container sensor.

cargo|@|ambient|humidity|#name#humiditysensor|#unit#percentage|input|actual|value = 80

Flow:

Air speed of 30 km/h affecting a reefer cargo.

terminal|@|ambient|@|air|flow|#name#flowsensor|#unit#km/h|output|actual|value = 30

Pressure:

A sensor in the terminal measuring a Pressure of 1013 hPa (1 atm)

terminal|@|ambient|@|air|pressure|#name#setpoint|#unit#hPa|input|actual|value = 1013

DewPoint:

The definition of dew point is the temperature point at which the air can hold no more water (water vapour) and is one of the factors in the heat index. It is always lower or the same as the air temperature. When the dew point is low, around 50 - 60°F/10 - 15°C, the air will feel comfortable.

O2

The level of O2 in the air

cargo|@|ambient|@|air|O2|#name#sensor|#unit#percentage|output|actual|value = 5

CO2

The level of CO2 in the air

cargo|@|ambient|@|air|CO2|#name#sensor|#unit#percentage|output|actual|value = 5

Nitrogen

The level of nitrogen in the air

cargo|@|ambient|@|air|nitrogen|#name#sensor|#unit#percentage|output|actual|value = 5

Lighting:

Sound:

 

Value

 

celsius; % percentage; CBH; hpa; mbar; km/h

 

Related standards

O

TIC Description

Related TIC4.0 definition

O

https://tic40.atlassian.net/l/cp/QykfBcSv; https://tic40.atlassian.net/l/cp/haZAujnm ; https://tic40.atlassian.net/l/cp/eEQQTACz ; Temperature ; Humidity; DewPoint; Volume; Flow;

TIC Description

Example

M

A reefer with a reading of the:

return temperature sensor of 15° C

cargo|@|air|temperature|#name#returnsensor1|#unit#celsius|output|actual|value = 15

and

a reading of the supply temperature sensor of 15° C

cargo|@|air|temperature|#name#supplysensor1|#unit#celsius|output|actual|value = 15

and

configured with a Humidity setpoint of 80%

cargo|@|air|humidity|#name#setpoint|#unit#percentage|input|actual|value = 80

and

configured with a Pressure setpoint of 1013 hPa (1 atm)

cargo|@|air|pressure|#name#setpoint|#unit#percentage|input|actual|value = 1013

TIC Description

Example in the context of the grammar

M

"cargo": [
        {
          "id": "ISO 6346",
          "isotypecode": "ISO 6346",
          "isotypecode1984": {
            "metaelements": [
              {
                "pom": "output",
                "pomt": "actual",
                "value": "1131 ISO 6346:1984",
                "name": "102 size and type",
                "description": "8154",
                "timestamp": "2024-05-17T09:24:27.544Z",
                "codelistresponsibleagencycode": "3055 5",
                "codelistresponsibleagencyname": "3055 ISO"
              }
            ]
          },
          "air": {
            "temperature": [
              {
                "name":"returnsensor1",
                "pom": "output",
                "pomt": "actual",
                "timestamp": "2024-05-17T09:24:27.545Z",
                "unit":"celsius",
                "value": 15
              },
              {
                "name":"supplysensor1",
                "pom": "output",
                "pomt": "actual",
                "timestamp": "2024-05-17T09:24:27.545Z",
                "unit":"celsius",
                "value": 15
              }
            ],
            "humidity": [
              {
                "name":"setpoint",
                "pom": "output",
                "pomt": "actual",
                "timestamp": "2024-05-17T09:24:27.545Z",
                "unit":"%",
                "value": 80
              }
            ],
            "ventilation": [
              {
                "pom": "output",
                "pomt": "actual",
                "timestamp": "2024-05-17T09:24:27.545Z",
                "value": false
              }
            ],
            "freevolume": [
              {
                "pom": "output",
                "pomt": "actual",
                "timestamp": "2024-05-17T09:24:27.545Z",
                "value": false
              }
            ],
            "flow": [
              {
                "pom": "output",
                "pomt": "actual",
                "timestamp": "2024-05-17T09:24:27.545Z",
                "value": false
              }
            ],
            "pressure": [
              {
                "name":"setpoint",
                "pom": "output",
                "pomt": "actual",
                "timestamp": "2024-05-17T09:24:27.545Z",
                "unit":"hPa",
                "value": 1013
              }
            ],
            "dewpoint": [
              {
                "pom": "output",
                "pomt": "actual",
                "timestamp": "2024-05-17T09:24:27.545Z",
                "value": false
              }
            ],
            "ionization": [
              {
                "pom": "output",
                "pomt": "actual",
                "timestamp": "2024-05-17T09:24:27.545Z",
                "value": false
              }
            ],
            "particulatematter": [
              {
                "pom": "output",
                "pomt": "actual",
                "timestamp": "2024-05-17T09:24:27.545Z",
                "value": false
              }
            ],
            "o2": [
              {
                "pom": "output",
                "pomt": "actual",
                "timestamp": "2024-05-17T09:24:27.545Z",
                "value": false
              }
            ],
            "co2": [
              {
                "pom": "output",
                "pomt": "actual",
                "timestamp": "2024-05-17T09:24:27.545Z",
                "value": false
              }
            ],
            "nitrogen": [
              {
                "pom": "output",
                "pomt": "actual",
                "timestamp": "2024-05-17T09:24:27.545Z",
                "value": false
              }
            ]
          }
        }
      ]
    }
  ]
}

TIC Description

Link to one or more operational processes

M

TIC Description

Search tags

M

#reefer #air #ambientair #cargo #setpoint

Technical

Version / Date

M

20240522

Technical

Internal TIC Version

M

first version

Technical

M = Mandatory

O = Optional


Created by

Edited by

Review / Approve

Published

Francisco Blanquer Jaraiz

Gonzalo Sandiás Corbillón (TIC4.0)

Identec Solutions (Main)

  • Sin etiquetas