TIC 4.0

Ventilation

CONCEPT

Fields

Type

Description

Purpose

Fields

Type

Description

Purpose

ID (Concept identifier)

M

ventilation

GRAMMAR

Concept name

M

Ventilation

GRAMMAR

Concept type

M

metadata

GRAMMAR

Also known as

O

air circulation, aeration

TIC Description

Definition

M

The action of allowing or/and push/pull air flow

 

Further Detail

O

In the context of a reefer container, ventilation is the action of allowing air from the outside to enter the cargo|@|reefer through the ventilation system, with the aim of maintaining the required internal air conditions for the type of commodity.

TIC Description

Required Information

M

SUBJECT; OBSERVED PROPERTY; POM; POMT and VALUE

TIC Description

SUBJECT

 

Cargo 2023.009 , CHE

 

POINT OF MEASUREMENT

 

POM: Input (represents the actual order given to a subject to perform in a specific way, also known as SETPOINT)

Output (represents the actual measurement from the sensors)

POMT: actual,

 

OBSERVED PROPERTY

 

Flow Exchange

The ventilation setting can be shown either as a percentage or as a value in cubicmeterspersecond, which stand for cubic meters per hour.

The CBM value indicates the amount of air moving into and out of the container within the given time frame, where a higher value signifies a greater ventilation rate.

A reefer configured with a ventilation setpoint of 15%

cargo|@|ventilation|flowexchange|input|actual|#unit#porcentage|value=15

 

Value

 

% percentage; cubicmeterperhour

 

Related standards

O

 

TIC Description

Related TIC4.0 definition

O

https://tic40.atlassian.net/l/cp/QykfBcSv; https://tic40.atlassian.net/l/cp/haZAujnm ; https://tic40.atlassian.net/l/cp/eEQQTACz ; Temperature ; Humidity; Volume; Flow;

TIC Description

Example

M

A reefer configured with a ventilation setpoint of 15%. The value means that the ventilation valve of the cargo|@|reefertype is open to 15%.

cargo|@|ventilation|flowexchange|input|actual|#unit#porcentage|value=15

TIC Description

Example in the context of the grammar

M

  "msg": {     "id": "",     "idthread": "",     "idsequence": "",     "sender": "",     "timestamp": "2024-08-09T07:00:32.441Z",     "topic": "",     "destination": "",     "creationtimestamp": null,     "starttimestamp": "2024-08-09T07:00:32.442Z",     "endtimestamp": "2024-08-09T07:00:32.442Z",     "version": "2022.009"   },   "tos": [     {       "id": "120SUPERCURRO2023",       "name": "TOS",       "number": 1,       "type": "",       "family": "",       "brand": "",       "model": "",       "cargo": [         {           "id": "ISO 6346",           "brand": "",           "isotypecode": "ISO 6346",           "isotypecode1984": {             "metaelements": [               {                 "pom": "output",                 "pomt": "actual",                 "value": "1131 ISO 6346:1984",                 "name": "102 size and type",                 "description": "8154",                 "timestamp": "2024-08-09T07:00:32.462Z",                 "codelistresponsibleagencycode": "3055 5",                 "codelistresponsibleagencyname": "3055 ISO"               }             ]           },           "ventilation": {             "flowexchange": [               {                 "pom": "input",                 "pomt": "actual",                 "timestamp": "2024-08-09T07:00:32.462Z",                 "unit": "%",                 "value": 15               }             ]           },

TIC Description

Link to one or more operational processes

M

 

TIC Description

Search tags

M

#reefer #air #ambientair #cargo #setpoint

Technical

Version / Date

M

20240522

Technical

Internal TIC Version

M

first version

Technical

M = Mandatory

O = Optional

 


 

Created by

Edited by

Review / Approve

Published

@Francisco Blanquer Jaraiz

Gonzalo Sandiás Corbillón (TIC4.0)

 

 

 

@Identec Solutions (Main)

 

 

 

© Copyright - TIC 4.0 All rights reserved | Design web by Fundación Valenciaport