CONCEPT
Fields | Type | Description | Purpose |
---|---|---|---|
ID (Concept identifier) | M | off | GRAMMAR |
Concept name | M | Off | GRAMMAR |
Concept type | M | status | GRAMMAR |
Also known as | O | Off; Not On; Power Off; Not ready to work; deep standby; No power; Engine off; Power supply off; turned off; Out of operations; idle; not running; | TIC Description |
Definition | M | If the main power supply or any system of the subject is not ready to operate (to do the job it has been designed for) the subject in less than 2 seconds then TRUE else FALSE | TIC Description |
Further Detail | O | This definition is complementary to the “on” concept. If the power supply system is not able to supply the energy for normal operation or the “control” of the subject is “off” or any of the subject systems or subsystems is not ready to run the subject for its normal “job” in less than 2 seconds then it is considered off. If any of the critical components to operate are not “on” then is considered “off”. | TIC Description |
Required Information | M | SUBJECT; OBSERVED PROPERTY and VALUE | TIC Description |
SUBJECT | M | #CHE; #STS; #SC; #RTG; #RMG; #TT; #FKL; #Gate; #Terminal; #MC; #TOS ; #Luminary | GRAMMAR |
POINT OF MEASUREMENT | O | #input;#internal_in ; #internal_out ;#output #schedule; #planning; #estimated; #actual; #performed | GRAMMAR |
OBSERVED PROPERTY | M | #status; #counter; #duration; #timer; #totaltimer #energy; #startevent; #startcounter; #endevent; #endcounter | GRAMMAR |
Value | M | TRUE; FALSE; integer; real number; | GRAMMAR |
Related standards | O | N/A | TIC Description |
Related TIC 4.0 definition | O | #on; #on_standby | TIC Description |
Example | M | che_off_status: TRUE = the Container Handler Equipment is not ready to operate or do its job properly in less than 2 seconds because no power, no control or any of its systems is not able to be ready on time. che_spreader_off_status: FALSE = the Spreader of the Container Handler Equipment is ready to operate properly (lock-unlock-expand-contract) in less than 2 seconds. che_engine_off_status: TRUE = the Engine of the Container Handler Equipment is not ready to generate the power to the CHE working properly in less than 2 seconds. TOS_off_status: TRUE = the complete system is not running and does not allow users or machines to login. | TIC Description |
Example in the context of the grammar | M | An RTG with the Engine On but the drivers off and the control off che_engine_off_status: FALSE; che_drivers_off_status: TRUE; che_control_off_status: TRUE; che_off_status: TRUE | TIC Description |
Link to one or more operational processes | M | Any CHE load or discharge operation. | TIC Description |
Search tags | M | #OFF; #Off; #off; #ON; #On; #on; #standby; #running; #working | Technical |
Version / Date | M | TIC_Q4_2020 / 15.09.2020 | Technical |
Internal TIC Version | M | definition technical group | Technical |
M = Mandatory
O = Optional
JSON:
XML:
MQTT:
Created by | Edited by | Review / Approve | Published |