CONCEPT

Fields

Type

Description

Purpose

ID (Concept identifier)

M

ambient

GRAMMAR

Concept name

M

Ambient

GRAMMAR

Concept type

M

metadata

GRAMMAR

Also known as

O

External atmosphere, external ambient.

TIC Description

Definition

M

It refers to the characteristics or conditions of the air in a specific location around a subject (CHE, cargo, terminal).

TIC Description

Further Detail

O

Different observed properties of the air in the ambient can affect, condition, or hinder the proper functioning of a subject (CHE, cargo).

In the context of a cargo|@|#typereefer#true, the ambient temperature may not be suitable for the heat transfer process, affecting the air (internal air of the cargo|@| #reefertype#true).

TIC Description

Required Information

M

SUBJECT; OBSERVED PROPERTY; POM; POMT and VALUE

TIC Description

SUBJECT

 

cargo; che; terminal

 

POINT OF MEASUREMENT

 

POM: Output (represents the actual measurement from the sensors) Input (represents the actual order given to a subject to perform in a specific way, also known as SETPOINT)

Output (represents the actual measurement from the sensors)

POMT: actual,

 

OBSERVED PROPERTY

 

#temperature, #humidity, #windspeed, #winddistance, #pressure, #O2level, #CO2level, #nitrogenlevel, #rainintensity, #rainflow, #soundpressure, #soundfrequency, #particulatematter.

 

Value

 

celsius; % percentage; CBHcubicmeterperhour; hpa; mbar; km/h

 

Related standards

O

TIC Description

Related TIC4.0 definition

O

https://tic40.atlassian.net/l/cp/QykfBcSv; https://tic40.atlassian.net/l/cp/haZAujnm ; https://tic40.atlassian.net/l/cp/eEQQTACz ; Temperature ; Humidity; DewPoint; Volume; Flow;

TIC Description

Example

M

In the context of a reefer with a reading of the:

ambient temperature sensor of 15° C

cargo|@|ambient|temperature|#unit#celsius|output|actual|#unit#celsius|value = 15

and

ambient humidity of 80%

cargo|@|ambient|@|air|humidity||#unit#percentage|output|actual|#unit#percentage|value = 80

and

ambient pressure of 1013 hPa (1 atm)

cargo|@|ambient|@|air|pressure|#unit#hPa|output|actual|#unit#hPa|value = 1013

In the context of a STS reading:

Wind of 30 km10 m/h s from the STS' anemometer:

che|@|ambienteambient|wind|output|atual|#unit#kilometer_per_hour#unit#meterpersecond|value = 3010

TIC Description

Example in the context of the grammar

M

In the context of a reefer with a reading of the:

Bloque de código
"msg": {
    "id": "",
    "idthread": "",
    "idsequence": "",
    "sender": "",
    "timestamp": "2024-08-02T07:42:54.184Z",
    "topic": "",
    "destination": "",
    "creationtimestamp": null,
    "starttimestamp": "2024-08-02T07:42:54.184Z",
    "endtimestamp": "2024-08-02T07:42:54.184Z",
    "version": "2022.009"
  },
  "tos": [
    {
      "id": "120SUPERCURRO2023",
      "name": "TOS",
      "number": 1,
      "type": "",
      "family": "",
      "brand": "",
      "model": "",
      "cargo": [
        {
          "ambient": {
            "temperature": [
              {
                "pom": "output",
                "pomt": "actual",
                "unit": "celsius",
                "timestamp": "2024-08-02T07:42:54.221Z",
                "value": 15
              }
            ],
            "humidity": [
              {
                "pom": "output",
                "pomt": "actual",
                "unit": "%",
                "timestamp": "2024-08-02T07:42:54.221Z",
                "value": 80
              }
            ],
            "flowexchange": [
              {
               "pom": "output",
                "pomt": "actual",
                "unit": "",
                "timestamp": "2024-08-02T07:42:54.221Z",
                "value": false
              }
            ],
            "wind": [
              {
                "pom": "output",
                "pomt": "actual",
                "unit": "",
                "timestamp": "2024-08-02T07:42:54.221Z",
                "value": false
              }
            ],
            "pressure": [
              {
               "pom": "output",
                "pomt": "actual",
                "unit": "hectopascals",
                "timestamp": "2024-08-02T07:42:54.221Z",
                "value": 1013
              }

In the context of a STS reading:

Bloque de código
{
  "msg": {
    "id": "",
    "idthread": "",
    "idsequence": "",
    "sender": "",
    "timestamp": "2024-06-07T16:05:23.207Z",
    "topic": "",
    "destination": "",
    "creationtimestamp": "2024-06-07T16:05:23.207Z",
    "starttimestamp": "2024-06-07T16:05:23.207Z",
    "endtimestamp": "2024-06-07T16:05:23.207Z",
    "version": "2024.0115"
  },
  "che": [
    {
      "id": "",
      "name": "",
      "number": 0,
      "type": "",
      "family": "",
      "brand": "",
      "model": "",
      "ambient": {
        "temperature": [
          {
            "pom": "output",
            "pomt": "actual",
            "unit": "celsius",
            "timestamp": "2024-06-07T16:05:23.292Z",
            "value": 0
          }
        ],
        "wind": [
          {
            "pom": "output",
            "pomt": "actual",
            "unit": "kilometer_per_hourmeterpersecond",
            "timestamp": "2024-06-07T16:05:23.292Z",
            "value": 3010
          },

TIC Description

Link to one or more operational processes

M

TIC Description

Search tags

M

#reefer #air #ambientair #cargo #setpoint

Technical

Version / Date

M

20240522

Technical

Internal TIC Version

M

first version