CONCEPT
Fields | Type | Description | Purpose | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ID (Concept identifier) | M | ambient | GRAMMAR | ||||||||||||||||||||
Concept name | M | Ambient | GRAMMAR | ||||||||||||||||||||
Concept type | M | metadata | GRAMMAR | ||||||||||||||||||||
Also known as | O | External atmosphere, external ambient. | TIC Description | ||||||||||||||||||||
Definition | M | Describes It refers to the external characteristics or conditions of the air in a given location in the surrounding of a subject where the specific location around a subject (CHE, cargo, terminal). | TIC Description | ||||||||||||||||||||
Further Detail | O | What are the environmental conditions surrounding a subject, in this case, a reefer container. Among the environmental conditions, we highlight concepts such as air, light, and sound. These conditions can affect the performance of different subjects (CHE, Cargo, Reefer Rack, Facilities). Typical op of ambien, temperature, pressuer, rainintensity/flow, windspeed, winddistance, radiation, particulate, CO2level, O2level, soundpreasure, soundfrequencyDifferent observed properties of the air in the ambient can affect, condition, or hinder the proper functioning of a subject (CHE, cargo). In the context of a cargo|@|#typereefer#true, the ambient temperature may not be suitable for the heat transfer process, affecting the air (internal air of the cargo|@| #reefertype#true). | TIC Description | ||||||||||||||||||||
Required Information | M | SUBJECT; OBSERVED PROPERTY; POM; POMT and VALUE | TIC Description | ||||||||||||||||||||
SUBJECT |
| cargo; che; terminal |
| ||||||||||||||||||||
POINT OF MEASUREMENT |
| POM: Output Input (represents the actual measurement from the sensorsorder given to a subject to perform in a specific way, also known as SETPOINT) Output (represents the actual measurement from the sensors)
POMT: actual, |
| ||||||||||||||||||||
OBSERVED PROPERTY | temperature, pressuer, rainintensity/flow, windspeed, winddistance, radiation, particulate, CO2level, O2level, soundpreasure, soundfrequency. 15 degrees Celsius of ambient temperature of the air measured by the reefer container sensor. cargo|@|ambient|temperature|#name#sensor1|#unit#celsius|output|actual|value = 15 Humidity: 80% of humidity in the ambient of the air measured by the reefer container sensor. cargo|@|ambient|humidity|#name#humiditysensor|#unit#percentage|input|actual|value = 80 Wind: Wind speed of 30 km/h affecting a reefer cargo. terminal|@|ambient|@|wind|#name#windsensor|#unit#km/h|output|actual|value = 30 Pressure: A sensor in the terminal measuring a Pressure of 1013 hPa (1 atm) terminal|@|ambient|@|pressure|#unit#hPa|output|actual|value = 1013 DewPoint: The definition of dew point is the temperature point at which the air can hold no more water (water vapour) and is one of the factors in the heat index. It is always lower or the same as the air temperature. When the dew point is low, around 50 - 60°F/10 - 15°C, the air will feel comfortable. O2 The level of O2 in the air cargo|@|ambient|@|O2|#name#sensor|#unit#percentage|output|actual|value = 5 CO2 The level of CO2 in the air cargo|@|ambient|@|CO2|#name#sensor|#unit#percentage|output|actual|value = 5 Nitrogen The level of nitrogen in the air cargo|@|ambient|@|air|nitrogen|#name#sensor|#unit#percentage|output|actual|value = 5 |
| Value |
| celsius; % percentage; CBH; hpa; mbar; km/h |
| Related standards | O | TIC Description | Related TIC4.0 definition | O | https://tic40.atlassian.net/l/cp/QykfBcSv; https://tic40.atlassian.net/l/cp/haZAujnm ; https://tic40.atlassian.net/l/cp/eEQQTACz ; Temperature ; Humidity; DewPoint; Volume; Flow; | TIC Description | Example | M | A reefer with a reading of the: ambient temperature sensor of 15° C cargo|@|ambient|@|air|temperature|#unit#celsius|output|actual|value = 15 and ambient Humidity of 80% cargo|@|ambient|@|air|humidity||#unit#percentage|output|actual|value = 80 and ambient Pressure of 1013 hPa (1 atm) cargo|@|ambient|@|air|pressure|#unit#hPa|output|actual|value = 1013 | TIC Description | Example in the context of the grammar | M | Bloque de código | #temperature, #humidity, #windspeed, #winddistance, #pressure, #O2level, #CO2level, #nitrogenlevel, #rainintensity, #rainflow, #soundpressure, #soundfrequency, #particulatematter. |
| |
Value |
| celsius; % percentage; cubicmeterperhour; hpa; mbar; km/h |
| ||||||||||||||||||||
Related standards | O | TIC Description | |||||||||||||||||||||
Related TIC4.0 definition | O | https://tic40.atlassian.net/l/cp/QykfBcSv; https://tic40.atlassian.net/l/cp/haZAujnm ; https://tic40.atlassian.net/l/cp/eEQQTACz ; Temperature ; Humidity; Volume; | TIC Description | ||||||||||||||||||||
Example | M | In the context of a reefer with a reading of the: ambient temperature sensor of 15° C cargo|@|ambient|temperature|output|actual|#unit#celsius|value = 15 and ambient humidity of 80% cargo|@|ambient|humidity|output|actual|#unit#percentage|value = 80 and ambient pressure of 1013 hPa (1 atm) cargo|@|ambient|pressure|output|actual|#unit#hPa|value = 1013 In the context of a STS reading: Wind of 10 m/s from the STS' anemometer: che|@|ambient|wind|output|atual|#unit#meterpersecond|value = 10 | TIC Description | ||||||||||||||||||||
Example in the context of the grammar | M | In the context of a reefer with a reading of the:
In the context of a STS reading:
| TIC Description | ||||||||||||||||||||
Link to one or more operational processes | M | TIC Description | |||||||||||||||||||||
Search tags | M | #reefer #air #ambientair #cargo #setpoint | Technical | ||||||||||||||||||||
Version / Date | M | 20240522 | Technical | ||||||||||||||||||||
Internal TIC Version | M | first version | Technical |
...