Fields | Type | Description | Purpose | |||||
---|---|---|---|---|---|---|---|---|
ID (Concept identifier) | M | warning | GRAMMAR | |||||
Concept name | M | Warning | GRAMMAR | |||||
Concept type | M | status | GRAMMAR | |||||
Also known as | O | Alarm, Caution, Advice | TIC Description | |||||
Definition | M | Warning is a condition in which the subject is close to fail on a required function, or a certain condition is not met to function normally, relevant to effect decision making over subject. | TIC Description | |||||
Further Detail | O | Attention, you may have to adjust your decision making, else you could run into a problem or a fault or interlock condition will persist. | TIC Description | |||||
Required Information | M | SUBJECT; OBSERVED PROPERTY and VALUE | TIC Description | |||||
SUBJECT | M | GRAMMAR | ||||||
POINT OF MEASUREMENT | O | ioutput estimated; actual; performed | GRAMMAR | |||||
OBSERVED PROPERTY | M | status; duration; level; counter; timer; totalcounter; totaltimer | GRAMMAR | |||||
Value | M | tic40codeid | GRAMMAR | |||||
Related standards | O | J1939 | TIC Description | |||||
Related TIC 4.0 definition | O | https://tic40.atlassian.net/l/c/pBWAiKtghttps://tic40.atlassian.net/l/c/sHgs2815 https://tic40.atlassian.net/l/c/jCkb1RZA https://tic40.atlassian.net/wiki/spaces/CRT/pages/878772453/ErrorMessage?atlOrigin=eyJpIjoiMTgwNWUyYzliYWNjNDE5MWIxZTFkYjQyOWI3ODVmZmIiLCJwIjoiYyJ9 https://tic40.atlassian.net/l/c/u01CZGna | TIC Description | |||||
Example | M | In flat format for an specific "timestamp": "2021-11-19T16:06:54.891Z" we receive this message: che.health.heallthy.status.ioutput.actual.boolean : TRUE che.health.fault.event.output.actual.tic40codeid: 1.1.2.4.3status.boolean : FALSE che.health.faultwarning.event.output.actual.tic40codename: che.powersource.coolant.control.sensorstatus.boolean: TRUE che.health.faultwarning.eventstatus.output.actual.oldvalue: FALSEtic40codeid: 1.1 che.health.faultwarning.event.output.actual.newvalue: FALSEtic40codeid: 1.1.4.45 che.health.warning.status.ioutput.actual.boolean: TRUEche.health.warning.status.ioutput.actual.tic40codeid: 1.1event.tic40codename: che.powersource.transmission.operatorpresence Means that the che health it is ok, without one specific fault in the coolant control sensor of the engine. But it is close to consider it as at fault so it has a general powersource but a interlock on the transmission give a warning in the powersource. Another more human readable example would be: an engine is close to overheat it’s coolant temperature, hence the CHE sends out a warning per TIC 4.0, which could mean operations planning the maintenance of cooler cleaning. | TIC Description | |||||
Example in the context of the grammar | M | Healthy problem with a simple fault data model in JSON format
| TIC Description | |||||
Link to one or more operational processes | M | TIC Description | ||||||
Search tags | M | Technical | ||||||
Version / Date | M | 2021.003 - 15/01/2022 | Technical | |||||
Internal TIC Version | M | 20211302021213 | Technical |