CONCEPT
Fields | Type | Description | Purpose | |||||
---|---|---|---|---|---|---|---|---|
ID (Concept identifier) | M | notstandby | GRAMMAR | |||||
Concept name | M | Not Standby | GRAMMAR | |||||
Concept type | M | status | GRAMMAR | |||||
Also known as | O | On; Not Off; Power On; Ready to work; running; With power; Engine on; Power supply on; idle; active; standby not active; | TIC Description | |||||
Definition | M | If the main power supply system and all subject systems are currently ready to operate (do the job it has been designed for) and no operator action is required (to be ready) then TRUE else FALSE | TIC Description | |||||
Further Detail | O | Standby is a special type of On status where the subject is currently ready and not in standby. If “off” is TRUE then “notstandby” has to be FALSE If “on” is TRUE and “standby” is FALSE then “notstandby” is TRUE If “on” is TRUE and “standby” is TRUE then “notstandby” is FALSE off_to_on_time = 5 (default if not value is consider) | TIC Description | |||||
Required Information | M | SUBJECT; OBSERVED PROPERTY and VALUE | TIC Description | |||||
SUBJECT |
| CHE; control; health; powersource; drive; spreader; hoist; trolley; boom; cabin; TOS; Terminal; Gate; TOS ; Luminary |
| |||||
POINT OF MEASUREMENT |
| input; iinput ; ioutput ;output schedule; planning; estimated; actual; performed |
| |||||
OBSERVED PROPERTY |
| status; duration; counter; totalcounter; timer; totaltimer |
| |||||
Value |
| status: boolean; duration and timer: seconds, totaltimer: hour. |
| |||||
Related standards | O |
| TIC Description | |||||
Related TIC 4.0 definition | O | https://tic40.atlassian.net/l/c/zf6c0sN4 https://tic40.atlassian.net/l/c/1Dz2Di1R https://tic40.atlassian.net/l/c/d9fFF9UV | TIC Description | |||||
Example | M | che.notstandby.status: FALSE = the Container Handler Equipment is not actually and currently ready to operate or do its job properly because the power, the control and all of its systems are not currently ready todo the job. che.spreader.notstandby.status: TRUE = the Spreader of the Container Handler Equipment is currently ready to operate properly (lock-unlock-expand-contract). che.engine.notstandby.status: FALSE = the Engine of the Container Handler Equipment currently is not ready to generate the power to the CHE working properly. | TIC Description | |||||
Example in the context of the grammar | M | An RTG with the Engine and control On but the drivers off and the cabin gate open che.engine.on.status: TRUE; che.drivers.on.status: FALSE; che.control.on.status: TRUE; che.cabingateopen.status: TRUE; che.on.status: TRUE; che.notstandby.status: FALSE JSON example:
| TIC Description | |||||
Link to one or more operational processes | M | Any CHE load or discharge operation. | TIC Description | |||||
Search tags | M | #OFF; #Off; #standby; #running; #working | Technical | |||||
Version / Date | M | 2021.1 - 30/04/2021 | Technical | |||||
Internal TIC Version | M | 20210422 consistency review 20210816 semantic off_to_on_time = | Technical |
M = Mandatory
O = Optional
...
Created by | Edited by | Review / Approve | Published |
Francisco Blanquer Jaraiz 2020-03-18 |
|
|
|
Francisco Blanquer Jaraiz 2021-04-22 |
|
| |
Francisco Blanquer Jaraiz 2021-08-16 |