Versiones comparadas

Clave

  • Se ha añadido esta línea.
  • Se ha eliminado esta línea.
  • El formato se ha cambiado.

CONCEPT

Fields

Type

Description

Purpose

ID (Concept identifier)

M

on_standby

GRAMMAR

Concept name

M

On Standby

GRAMMAR

Concept type

M

Activity

GRAMMAR

Also known as

O

On; Not Off; Power On; Ready to work; standby; With power; Engine on; Power supply on; idle;

TIC Description

Definition

M

If the subject is “On” On[If the main power supply and all subject systems are able to operate (do the job it has been designed for) the subject in less than 2 seconds requiring no more (a maximum) than one (not a sequence) operator action] but any (at least one) of them (power supply or subject system) is not currently ready then TRUE else FALSE

TIC Description

Further Detail

O

On Standby is a special type of On status where the subject is not currently ready but almost and just need a maximum of one operator action (a sequence from the operator is not required just one action).

If Off is TRUE then on_standby is FALSE

TIC Description

Required Information

M

SUBJECT; OBSERVED PROPERTY and VALUE

TIC Description

SUBJECT

 

#CHE; #Gate; #Terminal; #MC; #TOS ; #Luminary

 

POINT OF MEASUREMENT

 

#input;#internal_in ; #internal_out ;#output

#schedule; #planning; #estimated; #actual; #performed

 

OBSERVED PROPERTY

 

#status; #counter; #duration; #timer; #totaltimer #energy; #startevent; #startcounter; #endevent; #endcounter; #distance;

standby_to_operative_timer = 2 (default)

 

Value

 

TRUE; FALSE; real number; integer

 

Related standards

O

 

TIC Description

Related TIC 4.0 definition

O

#off; #on_standby

TIC Description

Example

M

che_on_standby_status: TRUE = the Container Handler Equipment is ready to operate or do its job properly in less than 2 seconds because the power, the control and all of its systems are able to be ready on time but currently is not.

che_spreader_on_standby_status: TRUE = the Spreader of the Container Handler Equipment is ready to operate properly (lock-unlock-expand-contract) in less than 2 seconds but currently is not.

che_engine_on_standby_status: FALSE = the Engine of the Container Handler Equipment is not ready to generate the power to the CHE working properly in less than 2 seconds but currently is not.

TIC Description

Example in the context of the grammar

M

An RTG with the Engine and control On but the drivers off and the cabin gate open

che_engine_on_status: TRUE; che_drivers_on_status: FALSE; che_control_on_status: TRUE; che_cabingateopen_status: TRUE; che_on_status: TRUE; che_on_standby_status: TRUE

CHE with the operator seated, engine standby (start-stop system), CHE ready to operate just when driver move the joystick then ON

che_engine_on_status: FALSE; che_control_on_status: TRUE; che_seat_operator_on_status: TRUE; che_on_status: TRUE; che_on_standby_status: TRUE

CHE with the operator not seated, engine standby (start-stop system), CHE ready to operate just when driver seated and move the joystick then OFF

che_engine_on_status: FALSE; che_control_on_status: TRUE; che_seat_operator_on_status: FALSE; che_on_status: FALSE; che_on_standby_status: FALSE

TIC Description

Link to one or more operational processes

M

Any CHE load or discharge operation.

TIC Description

Search tags

M

#OFF; #Off; #off; #ON; #On; #on; #standby; #running; #working

Technical

Version / Date

M

TIC_Q4_2020 / 15.09.2020

Technical

Internal TIC Version

M

definition technical group

Technical

...