Versiones comparadas

Clave

  • Se ha añadido esta línea.
  • Se ha eliminado esta línea.
  • El formato se ha cambiado.

CONCEPT

Fields

Type

Description

Purpose

ID (Concept identifier)

M

on_standby

GRAMMAR

Concept name

M

On Standby

GRAMMAR

Concept type

M

Activity

GRAMMAR

Also known as

O

On; Not Off; Power On; Ready to work; standby; With power; Engine on; Power supply on; idle;

TIC Description

Definition

M

If the main power supply system and all subject systems are ready to operate (do the job it has been designed for) in less than 2 seconds with maximum of one operation action but any (at least one) of them is not currently ready then TRUE else FALSE

TIC Description

Further Detail

O

On Standby is a special type of On status where the subject is not currently ready but almost and just need a maximum of one operation action.

If Off is TRUE then on_standby is FALSE

Example: On == true when RTG crane main power is on, variable frequency driver are switched on but the crane is not currently hoisting, traversing (trolley) or travelling (gantry). The operator needs to move a joystick or press a button on the control station to start an action.

TIC Description

Required Information

M

SUBJECT; OBSERVED PROPERTY and VALUE

TIC Description

SUBJECT

 

#CHE; #Gate; #Terminal; #MC; #TOS ; #Luminary

 

POINT OF MEASUREMENT

 

#input;#internal_in ; #internal_out ;#output

#schedule; #planning; #estimated; #actual; #performed

 

OBSERVED PROPERTY

 

#status; #counter; #duration; #timer; #totaltimer #energy; #startevent; #startcounter; #endevent; #endcounter; #distance;

standby_to_operative_timer = 2 (default)

 

Value

 

TRUE; FALSE; real number; integer

 

Related standards

O

 

TIC Description

Related TIC 4.0 definition

O

#off; #on_standby

TIC Description

Example

M

che_on_standby_status: TRUE = the Container Handler Equipment is ready to operate or do its job properly in less than 2 seconds because the power, the control and all of its systems are able to be ready on time but currently is not.

che_spreader_on_standby_status: TRUE = the Spreader of the Container Handler Equipment is ready to operate properly (lock-unlock-expand-contract) in less than 2 seconds but currently is not.

che_engine_on_standby_status: FALSE = the Engine of the Container Handler Equipment is not ready to generate the power to the CHE working properly in less than 2 seconds but currently is not.

TIC Description

Example in the context of the grammar

M

An RTG with the Engine and control On but the drivers off and the cabin gate open

che_engine_on_status: TRUE; che_drivers_on_status: FALSE; che_control_on_status: TRUE; che_cabingateopen_status: TRUE; che_on_status: TRUE; che_on_standby_status: TRUE

CHE with the operator seated, engine standby (start-stop system), CHE ready to operate just when driver move the joystick then ON

che_engine_on_status: FALSE; che_control_on_status: TRUE; che_seat_operator_on_status: TRUE; che_on_status: TRUE; che_on_standby_status: TRUE

CHE with the operator not seated, engine standby (start-stop system), CHE ready to operate just when driver seated and move the joystick then OFF

che_engine_on_status: FALSE; che_control_on_status: TRUE; che_seat_operator_on_status: FALSE; che_on_status: FALSE; che_on_standby_status: FALSE

TIC Description

Link to one or more operational processes

M

Any CHE load or discharge operation.

TIC Description

Search tags

M

#OFF; #Off; #off; #ON; #On; #on; #standby; #running; #working

Technical

Version / Date

M

TIC_Q4_2020 / 15.09.2020

Technical

Internal TIC Version

M

definition technical group

Technical

...