CONCEPT
Fields | Type | Description | Purpose | |||
---|---|---|---|---|---|---|
ID (Concept identifier) | M | off | GRAMMAR | |||
Concept name | M | Off | GRAMMAR | |||
Concept type | M | statusGRAMMAR |
|
|
| GRAMMAR |
Also known as | O | Off; Not On; Power Off; Not ready to work; deep standby; No power; Engine off; Power supply off; turned off; Out of operations; idle; not running; | TIC Description | |||
Definition | M | If the main power supply or any system of the subject is not ready to operate (to do the job it has been designed for) the subject in less than 2 seconds then TRUE else FALSE | TIC Description | |||
Further Detail | O | This definition is complementary to “on” concept. If the power supply system | TIC Description | |||
Required Information | M | SUBJECT; OBSERVED PROPERTY and VALUE | TIC Description | |||
SUBJECT | M | #CHE; #STS; #SC; #RTG; #RMG; #TT; #FKL; #Gate; #Terminal; #MC; #TOS ; #Luminary | GRAMMAR | |||
POINT OF MEASUREMENT | O | #input;#internal_in ; #internal_out ;#output #schedule; #planning; #estimated; #actual; #performed | GRAMMAR | |||
OBSERVED PROPERTY | M | #status; #counter; #duration; #timer; #totaltimer #energy; #startevent; #startcounter; #endevent; #endcounter | GRAMMAR | |||
Value | M | TRUE; FALSE; integer; real number; | GRAMMAR | |||
Related standards | O | N/A | TIC Description | |||
Related TIC 4.0 definition | O | #on; #on_standby | TIC Description | |||
Example | M | che_off_status: TRUE = the Container Handler Equipment is not ready to operate or do its job properly in less than 2 seconds because no power, no control or any of its systems is not able to be ready on time. che_spreader_off_status: FALSE = the Spreader of the Container Handler Equipment is ready to operate properly (lock-unlock-expand-contract) in less than 2 seconds. che_engine_off_status: TRUE = the Engine of the Container Handler Equipment is not ready to generate the power to the CHE working properly in less than 2 seconds. TOS_off_status: TRUE = the complete system is not running and does not allow users or machines to login. | TIC Description | |||
Example in the context of the grammar | M | An RTG with the Engine On but the drivers off and the control off che_engine_off_status: FALSE; che_drivers_off_status: TRUE; che_control_off_status: TRUE; che_off_status: TRUE | TIC Description | |||
Link to one or more operational processes | M | Any CHE load or discharge operation. | TIC Description | |||
Search tags | M | #OFF; #Off; #off; #ON; #On; #on; #standby; #running; #working | Technical | |||
Version / Date | M | TIC_Q4_2020 / 15.09.2020 | Technical | |||
Internal TIC Version | M | definition technical group | Technical |
M = Mandatory
O = Optional
OLD PROPOSAL
CONCEPT
...
ID
...
36
...
Name
...
CHE Activity Off
...
Abbreviation
...
che.activity.off.command||request||feedback||action.status||counter||timer||energy||distance
...
Category
...
(optional) Tag (Activity, Move, Functional, Operational, OS, etc) groups at a high level the property concept and establish a hierarchy. It is a tag that helps to identify and describe the property. The objective helps the human to classify, find, use the properties. Ie: move; activity; functional, operational, control, TOS. One concept can have several families but must be a closed list.
...
Also known as
...
Engine off; power supply off
...
Definition
...
If main power supply is available to operate in less than 2 seconds then false else true
...
Further Detail
...
If the machine is able to supply the energy for normal operation in less than 2 seconds then is consider On even if there is not main power supply running (ie CHE_Activity_On_Standby : true
This definition is complementary to CHE_Activity_On_Standby
...
Required
...
Related standards
...
Related TIC 4.0 definition
HEADER
Info |
---|
Identifies the message in origin, destination, time and unique reference (use this link for more information) |
...
Mandatory
...
Header message timestamp; Header message identifier; Header sender identifier; Header time; Header time start; Header time end
...
Optional
...
(Header topic; Header identifier)
SUBJECT
Info |
---|
Defines the perimeter and id of the subject (usually defined as a process) (use this link for more information) |
...
Default
...
Identifier (Abbreviation, Definition, Long definition); Class (Abbreviation, Definition, Long definition, Suitable)
...
Suitable
...
Name; Number; Family; Subsystem (Abbreviation, Definition, Long definition, Suitable, Examples)
POINT OF MEASUREMENT
Info |
---|
It defines wherein the process (step, place or time) the observed property of the concept is measured (use this link for more information) |
...
Default
...
IN; Request; Feedback; OUT (scheduled; planning; estimated, calculated; actual; verified)
...
Optional
...
Control (from where)
OBSERVED PROPERTY
Info |
---|
It is the magnitude of the concept (units, volume, weight, energy, time, etc.) (use this link for more information) |
...
Default
...
Status; %; Speed; Counter; Distance; Timer; Energy; Average; …
...
Suitable
...
Specify units when they are different than the International System
...
Units
...
True/False
Draws
Info |
---|
(optional) add some draws to explain the concept |
Diagrams
Info |
---|
(optional) add some process diagram which concept belongs |
Attached documents
Info |
---|
(optional) add some document to explain the concept |
Examples
Human
1.20191205 12:00 London-Gate03 move “get_in” “out=result” actual boxes “1”
2.20191205 12:06 London-TZ01 move “occupied” in actual boxes “1”
3.20191205 12:18 London-SC74 move “in” actual boxes “1” (waiting for orders)
4.20191205 12:22 London-SC74 move “Lock” actual boxes “1”
5.20191205 12:22 London-TZ01 move out actual boxes “1”
...
...
JSON:
XML:
MQTT:
Created by | Edited by | Review / Approve | Published |
...