RMS to TOS Example | Type | TIC4.0 | Description | ||
ContainerID |
|
| string | cargo|ID | Cargo identification |
Events |
|
| array |
|
|
| ContainerConnected |
| boolean | cargo|@|plugged|status|output|actual|value | Cargo plugged into the power source. |
| ContainerPowered |
| boolean | cargo|@|powered|status|output|actual|value | Cargo receiving power. |
| Time |
| number | cargo|@|powered|output|actual|timestamp | Time during which those statuses have been recorded. |
MonitoringData |
|
| array |
| In the following array, the monitoring data is grouped. |
| MonitoringTime |
| number |
| It is the time during which all data from the cargo sensors have been recorded. |
| SensorData |
| array |
|
|
|
| AmbientTemperature | number | cargo|@|ambient|temperature|output|actual|value | It refers to the air temperature outside the cargo. |
|
| CO2 | number | cargo|@|air|co2level|output|actual|value | CO2 level in the air inside the cargo |
|
| Humidity | number | cargo|@|air|humiditylevel|output|actual|value | Humidity in the air inside the cargo |
|
| O2 | number | cargo|@|air|o2level|output|actual|value | O2 level in the air inside the cargo |
|
| ReturnTemperature | number | cargo|@|air|temperature|#name#returnsensor1|output|actual|value | Air temperature measured by the "returnsensor" |
|
| SupplyTemperature | number | cargo|@|air|temperature|#name#supplysensor1|output|actual|value | Air temperature measured by the "supplysensor" |
|
| USDA1 | number | cargo|@|air|temperature|#name#usda1|output|actual|value | Air temperature measured by the "USDA1" sensor |
|
| USDA2 | number | cargo|@|air|temperature|#name#usda2|output|actual|value | Air temperature measured by the "USDA2" sensor |
|
| USDA3 | number | cargo|@|air|temperature|#name#usda3|output|actual|value | Air temperature measured by the "USDA3" sensor |
|
| USDA4 | number | cargo|@|air|temperature|#name#usda4|output|actual|value | Air temperature measured by the "USDA4" sensor |
|
| Ventilation | number | cargo|@|powersource|@|ventilationsystem|running|load|output|actual|value | Measurement of the ventilation level at which the ventilation system is running |
| SetpointData |
| array |
| The following is the data group indicating the SETPOINTS configured for that cargo. |
|
| CO2Setpoint | number | cargo|@|air|CO2level|input|actual|value | CO2 level to which the cargo was configured. In TIC4.0, the POM input refers to the SETPOINT. |
|
| HumidityActive | boolean | cargo|@|powersource|@|humuditysystem|@|active|status|output|actual|value | It refers to whether the humidity control system is active. |
|
| HumiditySetpoint | number | cargo|@|air|humiditylevel|input|actual|value | Level of Humidity in the air to which the cargo was configured. In TIC4.0, the POM input refers to the SETPOINT. |
|
| O2Setpoint | number | cargo|@|air|O2level|input||actual|value | O2 level to which the cargo was configured. In TIC4.0, the POM input refers to the SETPOINT. |
|
| TemperatureSetpoint | number | cargo|@|air|temperature|input|acutal|value | Temperature of the air to which the cargo was configured. In TIC4.0, the POM input refers to the SETPOINT. |
VisitHeader |
|
| array |
|
|
| Brand |
| string | cargocargo|@|control|brand | Cargo control brand |
| ContainerID |
| string | cargo|ID | Cargo identification |
| ControllerType |
| string | cargo|@|control|model | Cargo control model |
| Location |
| string | cargovisit cargovisit|@|location|logical|ioutput|actual|value | Determines the position in the yard where the container is located within the terminal. |
| VisitClosed |
| boolean | cargovisit|@|checkedout|status|input|actual|value | Determines whether the cargo is still within the terminal or if the cargovisit has concluded. |
...
Example TOS to RMS | Type | TIC4.0 | Notes | ||
ContainerData |
|
| array |
|
|
|
| Brand | string | tos|@|cargo|@|control|brand | Cargo control brand |
|
| ContainerID | number | tos|@|cargo|ID | Cargo identification |
|
| ControllerType | string | tos|@|cargo|@|control|model | Cargo control model |
|
| Location |
| cargovisit|@|location|logical|ioutput|actual|value | Determines the position in the yard where the container is located within the terminal. |
|
| ArrivalTime | time | tos|@|cargovisit|@|checkin|time|output|actual|timestamp | It is the time when the cargo visit entered the terminal. |
|
| PlannedDepartureTime | time | tos|@|cargovisit|@|checkout|time|output|planned|timestamp | It is the time by which the cargo visit is planned to be completed. |
| SetpointData |
| array |
| These are the data incorporated into the TOS from the cargo visit manifests, typically from the booking. |
|
| CO2Setpoint | number | tos|@|cargovisit|@|air|CO2level|imput|actual|value | The CO2 level in the air that the cargo should be at according to the manifest. |
|
| HumiditySetpoint | number | tos|@|cargovisit|@|air|humidity|imput|actual|value | The humidity level in the air that the cargo should be at according to the manifest. |
|
| O2Setpoint | number | tos|@|cargovisit|@|air|O2level|imput|actual|value | The O2 level in the air that the cargo should be at according to the manifest. |
|
| TemperatureSetpoint | number | tos|@|cargovisit|@|air|temperature|imput|actual|value | The temperature of the air that the cargo should be at according to the manifest. |
|
| VentilationSetpoint | number | tos|@|cargovisit|@|ventilationsystem|@|running|load|input|actual|value | The ventilation setting that should be in place according to the manifest. |
|
| CO2Maximum | number | tos|@|cargovisit|@|air|CO2level|input|actual|maximum | The maximum CO2 level in the air that the cargo should be at according to the manifest. |
|
| CO2Minimum | number | tos|@|cargovisit|@|air|CO2level|input|actual|minimum | The minimum CO2 level in the air that the cargo should be at according to the manifest. |
|
| HumidityMaximum | number | tos|@|cargovisit|@|air|humidity|input|actual|maximum | The maximum humidity level in the air that the cargo should be at according to the manifest. |
|
| HumidityMinimum | number | tos|@|cargovisit|@|air|humidity|input|actual|minimum | The minimum humidity level in the air that the cargo should be at according to the manifest. |
|
| O2Maximum | number | tos|@|cargovisit|@|air|O2level|input|actual|maximum | The maximum O2 level in the air that the cargo should be at according to the manifest. |
|
| O2Minimum | number | tos|@|cargovisit|@|air|O2level|input|actual|minimum | The minimum O2 level in the air that the cargo should be at according to the manifest. |
|
| TemperatureMaximum | number | tos|@|cargovisit|@|air|temperature|input|actual|maximum | The maximum temperature of the air that the cargo should be at according to the manifest. |
|
| TemperatureMinimum | number | tos|@|cargovisit|@|air|temperature|input|actual|minimum | The minimum temperature of the air that the cargo should be at according to the manifest. |